THREAD MEASUREMENT INSERTS
Information (*rq=Request Quote)
Thread inserts types 21, 22 & 23 are for threads with a 55º - 80º flank angle. Typical threads within this range are M, MF, UNC, UNF, UNEF, UNS, UNJ. G (BSPP), NPS & Pg
Thread inserts types 21, 22 & 23 are for threads with a 55º - 80º flank angle. Typical threads within this range are M, MF, UNC, UNF, UNEF, UNS, UNJ. G (BSPP), NPS & Pg
For pitches between 0.5-1 mm/48-24 TPI
For pitches between 1-2 mm/24-13 TPI
For pitches between 2-4 mm/13-6 TPI
For pitches between 2-4 mm/6-3 TPI
For pitches between 4-8 mm/3-2 TPI
Made to customer specification
Internal Pitch Diameter from 6mm/0.25” (D2)
For pitches between 0.5-1 mm/48-24 TPI
For pitches between 1-2 mm/24-13 TPI
For pitches between 2-4 mm/13-6 TPI
For pitches between 2-4 mm/6-3 TPI
Made to customer specification
Internal Pitch Diameter from 36mm/1.375” (D2)
For pitches between 0.5-1 mm/48-24 TPI
For pitches between 1-2 mm/24-13 TPI
For pitches between 2-4 mm/13-6 TPI
For pitches between 2-4 mm/6-3 TPI
For pitches between 4-8 mm/3-2 TPI
Made to customer specification
Because of the flank angle (Tr 30º and ASME 29º) these require a FMS insert for each specific pitch.
For Tr and ACME external pitch diameter
For Tr and ACME internal pitch diameter from 6mm/0.25”
For Tr and ACME internal pitch diameter from 36mm/1.375”
For Rd (Knuckle), Buttress & API external pitch diameter
For Rd (Knuckle), Buttress & API internal pitch diameter from 6mm/0.25”
For Rd (Knuckle), Buttress & API internal pitch diameter from 36mm/1.375”
THREAD INSERTS FOR R, Rc (BSPT) & NPT
For external taper threads from 1/8” and over.
For internal taper threads from 1/8” and over.
Insert types 24A & 25A require calibration plate 30A
For thread insert types 21, 22 & 23 with pitches from 1-4mm/6 TPI
For thread insert types 21, 22 & 23 with pitches from 0.5-8 mm/48-3TPI
For thread inserts intended for threads with flank angles not between 55º to 80º
Certificates (where these are required) are carried out by a certified calibration lab.
FMS calibration plates do not normally require recertification as there is virtually no wear from calibration. Probably the only time necessary is if the plate is dropped or mishandled.
FMS calibration plates do not normally require recertification as there is virtually no wear from calibration. Probably the only time necessary is if the plate is dropped or mishandled.
Insert holders for calipers with a jaw thickness of max. 4mm/0.155”
Insert holders for calipers with a jaw thickness of max. 6.5mm/0.155”
Insert holders made to customer requirement
Caliper pressure device for calipers up to 200mm/8”
Caliper pressure device for calipers up to 600mm/24”
Caliper pressure device made to customer requirements
Bushes for M2.5 dial probes
Dial probes can be used for external and internal measurement including wall thickness.
Useful when measuring many external threads with the same diam. or long threaded items.
For external recesses & grooves
For internal recesses & grooves. Min. hole diameter 5mm/0.2” and measurement depth of max. 15mm/0.6”
For internal recesses & grooves. Min. hole diameter 5mm/0.2” and measurement depth of max. 15mm/0.6”
For internal recesses & grooves. Min. hole diameter 10mm/0.4” and measurement depth of max. 30mm/1.2”
For internal recesses & grooves. Min. hole diameter 10mm/0.4” and measurement depth of max. 30mm/1.2”
For internal recesses & grooves and measurement depth of max.
For internal recesses & grooves and measurement depth of max.
Made to customer requirements. Best to send a drawing or sketch of what is to be measured.